| GF72.29-P-3004A | Convenience opening of power windows function | 22.1.97 |
| |||
Function prerequisites
No overvoltage/undervoltage
circuit 15 off and
circuit 15R off and
circuit 15c off.
Function Each door control module (N69/1) or (N69/2), (MODELS 202/210 also N69/3 or N69/4) receives over CAN the request for convenience opening and then actuates the power window motor. The motor is actuated until the door control module |
detects through position recognition that the window is completely open. The convenience opening function of the power window is also performed for non-normalized windows.
The convenience opening function of the power windows is aborted if the request over CAN is no longer received or
lock-up of the power window is detected or
the function requirements listed above are no longer satisfied.
|
|
Position recognition for power windows | GF72.29-P-4000A | |
|
Lock up recognition for power windows | GF72.29-P-4001A | |
|
Synchronization of power windows | GF72.29-P-4003A | |
|
Convenience closing of the power windows | GF72.29-P-3005A |